LCP01A – Load Cell Protector

  • Six wires and shield protection works with four or six wire systems
  • Suitable for compression or tension cells
  • Low series impedance, loadcells do not need recalibration
  • NEMA®-12 (IP-55) rated, suitable for outdoor use
  • Helps protect against excitation over-voltage and prevent loadcell damage

 

SPECIFICATIONS TABLE

Part NumberLCP01A
Article Number701610
Max Discharge Current (Imax), Shield to Ground10 kA 8/20 μs
Max Discharge Current (Imax), Signal to Shield0.3 kA 8/20 μs
Voltage Protection Level (Up), Shield to Ground90 V
Voltage Protection Level (Up), Signal to Shield30 V
Voltage Protection Level (Up), Signal to Signal15 V
Loop Resistance0.3 Ω
TechnologySilicon Avalanche Diode (SAD)
MaterialAcrylonitrile Butadiene Styrene
Enclosure RatingNEMA® 12 (IP55)
Depth (D)110 mm
Height (H)56 mm
Width (W)75 mm
Unit Weight0.25 kg
Temperature-40 to 80 °C
Standard Packaging Quantity1 pc
UPC78285644014
EAN-139321098000804

You may also like...