LS25-150 Series

Single Output General Purpose AC/DC Power Supplies

A Power Supply that Protects Your Equipment

LS series are not only designed to meet the harmonic current standard (IEC61000-3-2,-3), but also to pass this standard with enough margin so that equipment will be well protected against overheating and malfunction. In addition to conformance to the international standards, LS series have less than 1mA leakage current and ability to withstand 300VAC surge for 5 seconds for better safety and protection

Compact Size

LS Series are smaller than current models in which can give more flexibility in design. This compact design is ideal for application including indoor display, self-service kiosk, and vending machines.

Economical and Environmental Friendly

High-efficiency power output will reduce the amount of wasted energy. Strict evaluation of components used will also reduce defect. Therefore, user’s overall running cost
can be minimized.

Wide Operating Temperatures

LS series are designed to operate reliably between -25°C to 50°C at 100% load and up to 70°C at derated load. This feature is the best solution for equipment to run in extreme environments.*Refer to each model specification for derating

Low and High Voltage Full Line Up

LS series cover most of the output voltage to cater wide range of applications. The available 36V is suitable for applications like printer head or LED display panel.

SERIES TABLE

ModelVoltageAdjust Range (V)Max Current (A)Efficiency (typ) %
LS25-3.33.3V2.85 – 3.6672
LS25-55V4.5 – 5.5577
LS25-1212V10.8 – 13.22.179
LS25-1515V13.5 – 16.51.782
LS25-2424V22 – 27.61.184
LS25-3636V32 – 400.7585
LS25-4848V42 – 540.5785
LS35-3.33.3V2.85 – 3.6773
LS35-55V4.5 – 5.5777
LS35-1212V10.8 – 13.2381
LS35-1515V13.5 – 16.52.483
LS35-2424V22 – 27.61.584
LS35-3636V32 – 40184
LS35-4848V42 – 540.884
LS50-3.33.3V3.0 – 3.61075
LS50-55V4.75 – 5.51080
LS50-1212V10.8 – 13.24.284
LS50-1515V13.5 – 16.53.485
LS50-2424V22 – 27.22.286
LS50-3636V32 – 401.486
LS50-4848V42 – 541.186
LS75-3.33.3V3.0 – 3.61575
LS75-55V4.75 – 5.51279
LS75-1212V10.8 – 13.2684
LS75-1515V13.5 – 16.5585
LS75-2424V22 – 27.23.286
LS75-3636V32 – 402.186
LS75-4848V42 – 541.687
LS100-3.33.3V3.0 – 3.62074
LS100-55V4.75 – 5.51677
LS100-1212V10.8 – 13.28.581
LS100-1515V13.5 – 16.5782
LS100-2424V22 – 27.24.584
LS100-3636V32 – 40384
LS100-4848V42 – 542.384
LS150-3.33.3V3.0 – 3.63074
LS150-55V4.75 – 5.52678
LS150-1212V10.8 – 13.212.583
LS150-1515V13.5 – 16.51084
LS150-2424V22 – 27.26.586
LS150-3636V32 – 404.386
LS150-4848V42 – 543.387

SPECIFICATIONS TABLE

AC and DC Input Voltage (300VAC for 5s)LS25 – LS100:  88 ~ 264VAC ( 125-373VDC )
LS150:  88-132 / 176-264VAC
Switch selectable )   ( 248-373VDC )
Power FactorMeets EN61000-3-2, -3
Temperature Coefficient<0.02%/°C (0 – 50°C)
Overcurrent Protection> 110%
Leakage Current (230VAC 60Hz)<1mA
Remote SenseNo
LED IndicatorGreen LED = On
Operating Temperature-25 to +70°C.  Derate linearly to 50% load from +50 to +70°C (2)
Storage Temperature-40 to +85°C
Operating Humidity20 – 90% RH (non condensing)
Storage Humidity10 – 95% RH (non condensing)
CoolingConvection
Withstand VoltageInput to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)10 – 55Hz: 19.6m/s2 constant sweep 1 min X, Y, Z for 1 hour
Shock< 196.1 m/s2 (20G)
ImmunityIEC61000-4-2, -3, -4, -5, -6, -8, -11
Safety Agency ApprovalsUL60950-1, EN60950-1, IEC60950-1, CE Mark
Conducted & Radiated EMIEN55011/EN55022-B, FCC-B