Our website features a wide range of standard power conversion and backup products, but we also have the capacity and capability to design and manufacture custom solutions to meet your specific application needs. Contact our team of experienced engineers today to discuss your project. Dismiss
Backed by the same limited lifetime warranty as the HWS series, the HWS300P and HWS600P models offer a 300% peak power rating for 5 seconds. The HWS-P series deliver average power levels of 300 and 600W and are available with 24V, 36V and 48V output voltages.
Model | Voltage V | Adjust Range V | Max Avg. Current A | Overvoltage V |
HWS300P-24 | 24V | 19.2 – 26.4 | 12.5 | 27.6 – 32.4 |
HWS600P-24 | 24V | 19.2 – 26.4 | 25 | 27.6 – 32.4 |
HWS300P-36 | 36V | 28.8 – 39.6 | 8.4 | 41.4 – 48.6 |
HWS600P-36 | 36V | 28.8 – 39.6 | 16.7 | 41.4 – 48.6 |
HWS300P-48 | 48V | 38.4 – 52.8 | 6.3 | 55.2 – 64.8 |
HWS600P-48 | 48V | 38.4 – 52.8 | 12.5 | 55.2 – 64.8 |
Input Voltage Range | 85 – 265VAC (47 – 63Hz) or 120 – 330VDC |
Input Current (Typ) | See Datasheet |
Inrush Current | 20 /40 100/200VAC |
Power Factor | Meets EN61000-3-2 |
Temperature Coefficient | <0.02%/°C |
Overcurrent Protection | See Datasheet |
Overvoltage Protection | See Datasheet |
Hold Up Time (Typ) | 20 ms |
Leakage Current (max) | <0.75mA (Typically 0.2mA at 100VAC) |
Indicator | Green LED = ON |
Operating Temperature (with cover) | -10°C to +70°C, derate linearly to 50% load from 50°C to 70°C |
Storage Temperature | -30°C to +85°C |
Humidity (non condensing) | Operating: 10 – 90%RH, Non operating 10 – 95%RH |
Cooling | Internal fan |
Withstand Voltage | Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. |
Isolation Resistance | >100MΩ at 25°C & 70%RH, Output to Ground 500VDC |
Vibration (non operating) | 10 – 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour |
Shock | < 196.1 m/s2 |
Safety Agency Approvals | UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark |
Line Dip | Complies with SEMI F47 (200VAC line only) |
Conducted & Radiated EMI | EN55011 / EN55022, FCC VCCI Class B |
Immunity | IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 |
Weight (Typ) | See Datasheet |
Size (HxWxD) (with cover) | See Datasheet |
MTBF | See Datasheet |