Our website features a wide range of standard power conversion and backup products, but we also have the capacity and capability to design and manufacture custom solutions to meet your specific application needs. Contact our team of experienced engineers today to discuss your project. Dismiss
The ECS25, 45 & 60 Series has been designed to minimise the no-load power consumption and maximise efficiency in order to facilitate equipment design to the latest environmental legislation.
Approved for Class I and Class II applications, this range of single output AC-DC power supplies feature very high convection cooled power density in an industry-leading 2″ x 3″ (51.0 mm x 76.2 mm) footprint. The very low profile, 1U compatible supplies meet EN55011/22 Level B conducted emissions with low earth leakage currents of 80 µA at 115 VAC or 160 µA at 230 VAC. Making these switchers ideal for industrial, IT and medical applications. The series has single output versions from 5 V to 48 VDC, adjustable by ±10%. They are dual-fused for compliance with IEC60601-1 and efficiency up to 89%, so minimal excess heat is generated. They will deliver up to 60 W of power at +50 °C and up to +70 °C with derating.
Model | Input | Output | Power |
ECS25US12 | 80 to 264 Vac | 12 V / 2.08 A | 25W |
ECS25US15 | 80 to 264 Vac | 15 V / 1.67 A | 25W |
ECS25US24 | 80 to 264 Vac | 24 V / 1.04 A | 25W |
ECS25US48 | 80 to 264 Vac | 48 V / 0.52 A | 25W |
ECS45US05 | 80 to 264 Vac | 5 V / 6 A | 45W |
ECS45US12 | 80 to 264 Vac | 12 V / 3.75 A | 45W |
ECS45US15 | 80 to 264 Vac | 15 V / 3 A | 45W |
ECS45US24 | 80 to 264 Vac | 24 V / 1.9 A | 45W |
ECS45US48 | 80 to 264 Vac | 48 V / 0.95 A | 45W |
ECS60US05 | 80 to 264 Vac | 5 V / 8 A | 60W |
ECS60US12 | 80 to 264 Vac | 12 V / 5 A | 60W |
ECS60US15 | 80 to 264 Vac | 15 V / 4 A | 60W |
ECS60US24 | 80 to 264 Vac | 24 V / 2.5 A | 60W |
ECS60US48 | 80 to 264 Vac | 48 V / 1.25 A | 60W |
Harmonic Currents: | EN61000-3-2, class A |
Efficiency: | up to 90% typical |
Operating Temp: | -20 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C |
Isolation: | 4000 VAC Input to Output 2 x MOPP |
1500 VAC Input to Ground 1 x MOPP | |
500 VDC Output to Ground 1 x MOPP | |
Worldwide Safety Approvals: | IEC60950-1 |
European Safety Approvals: | EN60950-1 |
US Safety Approvals: | UL60950-1, CSA22.2 No. 234 per cUL |
EMC: | EN55011/22 level B conducted. |
45 & 60 W: EN55011/22 level A radiated, | |
ECS25 & some ECS60 models: level B radiated |
© Copyright Helios Power Solutions 2024