The Genesys™ 2U Full-Rack (GEN-2U) series of 5000W DC Programmable Power Supplies provides high power density (up to 5200W) with a complete set of user-friendly interfaces within a 2U profile.
This series offers Output voltages from 8V (@ 600A) to 600V (@ 8.5A) in both a Three-phase 208VAC Input (170-265VAC, 47-63Hz) and Three-phase 400VAC Input (342-460VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load).
Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant), USB (2.0 compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.
All models are CE Marked in accordance with the Low Voltage and EMC Directives, are RoHS compliant, have worldwide Safety Angency approvals (UL/cUL 60950-1 and EN 60950-1 listed) and offer a five (5) year Warranty.
Model | Output Voltage (VDC) | Output Current ( A ) | Output Power ( W ) |
GEN 8-600 | 0~8V | 0~600 | 4800 |
GEN 10-500 | 0~10V | 0~500 | 5000 |
GEN 16-310 | 0~16V | 0~310 | 4960 |
GEN 20-250 | 0~20V | 0~250 | 5000 |
GEN 30-170 | 0~30V | 0~170 | 5100 |
GEN 40-125 | 0~40V | 0~125 | 5000 |
GEN 60-85 | 0~60V | 0~85 | 5100 |
GEN 80-65 | 0~80V | 0~65 | 5200 |
GEN 100-50 | 0~100V | 0~50 | 5000 |
GEN 150-34 | 0~150V | 0~34 | 5100 |
GEN 200-25 | 0~200V | 0~25 | 5000 |
GEN 300-17 | 0~300V | 0~17 | 5100 |
GEN 400-13 | 0~400V | 0~13 | 5200 |
GEN 500-10 | 0~500V | 0~10 | 5000 |
GEN 600-8.5 | 0~600V | 0~8.5 | 5100 |
Input Voltage / Frequency (range) | 3-Phase, 208V models: 170~265Vac, 47~63Hz , 3-Phase, 400V models: 342~460Vac, 47~63Hz |
Inrush Current | 3-Phase 208V models: Less than 50A, 3-Phase 400V models: Less than 20A |
Power Factor | 3-Phase models: 0.94@208/380Vac, rated output power. |
Parallel Operation | Up to 4 identical units in master/slave mode |
Operating temp | 0~50°C, 100% load. |
Storage temp | -20~85°C |
Operating humidity | 20~90% RH (non-condensing). |
Storage humidity | 10~95% RH (non-condensing). |
Vibration | MIL-810F, method 514.5, The EUT is fixed to the vibrating surface. |
Shock | Less than 20G, half sine, 11mSec. Unit is unpacked. |
Altitude | Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp. |
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m). | |
RoHS Compliance | Complies with the requirements of RoHS directive. |