GEN10-15 kW – Laboratory Power Supplies: 10kW -15kW

Brand: TDK LAMBDA

SKU: HPS-PS-LAB-GEN10-15KW
This product is available globally.
  • High Power Density 10 / 15KW in 3U.
  • Wide Range of popular worldwide 3 PHASE AC inputs.
  • Output Voltage up to 1500V.
  • Output Current up to 1000A.

Description

TDK – Lambda GEN10-15 kW

Laboratory Power Supplies: 10 kW -15 kW

The TDK – Lambda Genesys™ 3U Full-Rack (GEN-3U) series of 15kW DC Programmable Power Supplies provides high power density (up to 15kW) with a complete set of user-friendly interfaces within a 3U profile.

This series offers Output voltages from 30V (@ 500A) to 1500V (@ 10.0A) in a Three-phase 208VAC Input (180-253VAC, 47-63Hz), a Three-phase 400VAC Input (342-440VAC, 47-63Hz) and a Three-phase 480VAC Input (432-528VAC, 47-63Hz) all with Passive Power-Factor Correction (0.88 @ rated load).

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

SERIES TABLE

ModelOutput Voltage (Vdc)Output Current (Adc)Output Power (kW)
GEN 7.5-10000~7.50~10007.5
GEN 10-10000~100~100010
GEN 12.5-8000~12.5 0~80010
GEN 20-5000~200~50010
GEN 25-4000~250~40010
GEN 30-3330~300~33310
GEN 30-5000~300~50015
GEN 40-2500~400~25010
GEN 40-3750~400~37515
GEN 50-2000~500~20010
GEN 50-3000~500~30015
GEN 60-1670~600~16710
GEN 60-2500~600~25015
GEN 80-1250~800~12510
GEN 80-187.50~800~187.515
GEN 100-1000~1000~10010
GEN 100-1500~1000~15015
GEN 125-800~1000~8010
GEN 125-1200~1000~12015
GEN 150-660~1250~6610
GEN 150-1000~1250~10015
GEN 200-500~1500~5010
GEN 200-750~1500~7515
GEN 250-400~2500~4010
GEN 250-600~2500~6015
GEN 300-330~3000~3310
GEN 300-500~3000~5015
GEN 400-250~4000~2510
GEN 400-37.50~4000~37.515
GEN 500-200~5000~2010
GEN 500-300~5000~3015
GEN 600-170~6000~1710
GEN 600-250~6000~2515
GEN 800-12.50~8000~12.510
GEN 800-18.80~8000~18.815
GEN 1000-100~10000~1010
GEN 1000-150~10000~1515
GEN 1250-80~12500~810
GEN 1250-120~12500~1215
GEN 1500-6.70~15000~6.710
GEN 1500-100~15000~1015

SPECIFICATIONS TABLE

Input Voltage / Frequency (range)208VAC (180-253), 400VAC (360-440 , 342-440 (select 10kW/15kW models)), 480VAC (432-528); 47-63Hz (all)
No. of phases3-Phase (Wye or Delta) 4 wire total (3-Phase and 1 protective Earth ground)
Dropout Voltage180 / 360, 342 (select models) / 432; select models (10kW): 800V-1500V, select models (15kW): 30V-50V, 800V-1500V
Input Current (180VAC/360 or 342VAC/432VAC)10kW – 45/23/20 (Vout < 600V); N/A/23/20 (800V < Vout < 1500V) – at full rated Output power 15kW – 64/32/27 (Vout < 600V); N/A/32/27 (800V < Vout < 1500V) – at full rated Output power
Inrush CurrentNot to exceed full rated Input current (see para. above)
Power Factor0.88 Passive (typical)
Leakage Current3.5 (EN60950) max.
Input Protection208VAC: circuit breaker (Vout < 600V); 400VAC/480VAC (all models) – line fuse
Input Overvoltage ProtectionUnit shall not be damaged by line overvoltage of 120% nominal AC input voltage with maximum duration of 100usec.
Phase Imbalance≤ 5% on Three-Phase Input
Operating Temperature0 ~ +50°C, 100% load
Storage Temperature-20 ~ +70°C
Operating Humidity20 ~ 80% RH (non-condensing)
Storage Humidity10 ~ 90% RH (non-condensing)
Vibration & ShockASTM D4169, Standard Practice for Performance Testing of Shipping Containers and Systems, Shipping Unit: Single Package Assurance Level: Level II; Acceptance Criteria: Criterion 1 – No product damage Criterion 2 – Packaging is intact, Distribution Cycle: 12 – Air (intercity) and motor freight (local), unitized is used.
AltitudeOperating: +50°C up to 7500 ft. (2500m), +45°C from 7501 to 10,000ft (2501m – 3000m), Non-Operating 40,000 ft (12,000m)
Audible Noise65dBA at Io(rated) (measured 1m from front panel)