Vision Rack

Single Phase – Rack Mount AC UPS 800VA -1100VA

VERY HIGH PROTECTION
Within a Vision Rack, an Automatic Voltage Regulator (AVR) provides voltage stabilisation and protection from brownouts, sag and surge voltages. The AVR also helps to reduce battery usage and retain their charge for a complete mains power supply failure. Electro Magnetic Interference (EMI) filters provide further protection from spikes and transients.

When the mains power supply fails, the load is powered by the inverter and receives a true SINEWAVE supply for maximum power continuity and reliability.

HIGH AVAILABILITY
A Powershare output socket provides load shedding on mains power supply failure to maximise the back-up time available for critical loads.
Predictive battery testing helps to identify potential battery deterioration and failures.
Deep discharge protection helps to reduce overall battery aging.

VERSATILITY
VSR versions include an Emergency Power Off switch for complete electrical shutdown in emergency situations.
The “cold-start” function allows a Dialog Vision to start up on inverter when no mains power or alternative power supply is present.

ADVANCED COMMUNICATION

  • Advanced, multi-platform communication for all operating systems and network environments: PowerShield³ monitoring and shut-down software included, with SNMP agent, for Windows 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, VMWare ESX and other Unix operating systems.
  • Shutdown and Management Software downloadable.
  • Plug and play
  • USB port / Serial RS232 port / Communication Slot

Technical Specifications VSR800

ModelsVSR800
INPUT
Rated power800 VA
Voltage230
Frequency50/60 Hz with autorange
Frequency tolerance± 10Hz
OUTPUT and INVERTER OUTPUT
Rated power800 VA
Active power640 W
Number phases1
WaveformSinewave
Frequency50 or 60 Hz with autorange
BATTERIES
TypeMaintenance-free sealed lead acid
Typical recharge time2÷4 h
ENVIRONMENTAL
Altitude max1000 m at nominal power (-1% power for every 100 m above 1000 m) 4000 m maximum
ColorDark gray
Safety complianceEN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
EMC conformanceEN 62040-2 and Directive 2014/30/EU
Protection rating2
Surge capabilityIEC 801-5 6 KV 1.2 / 50 µs; 3KA 8 / 20 µs differential
ProtectionsOverload – short-circuit – overvoltage – undervoltage – temperature – low battery
Noise (at 1 m)<50 dBA at 1 m
Operating temperature0 ÷ 40 °C
Relative humidity5 – 95% no condensing
Output sockets4 IEC 10A
DATA
Weight13.5 kg
Dimensions (h w d)1Ux19″x460 mm

Technical Specifications VSR110

ModelsVSR 1100
INPUT
Rated power1100 VA
Voltage230
Frequency50/60 Hz with autorange
Frequency tolerance± 10Hz
OUTPUT and INVERTER OUTPUT
Rated power1100 VA
Active power880 W
Number phases1
WaveformSinewave
Frequency50 or 60 Hz with autorange
BATTERIES
TypeMaintenance-free sealed lead acid
Typical recharge time2÷4 h
ENVIRONMENTAL
Altitude max1000 m at nominal power (-1% power for every 100 m above 1000 m) 4000 m maximum
ColorDark gray
Safety complianceEN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
EMC conformanceEN 62040-2 and Directive 2014/30/EU
Protection rating2
Surge capabilityIEC 801-5 6 KV 1.2 / 50 µs; 3KA 8 / 20 µs differential
ProtectionsOverload – short-circuit – overvoltage – undervoltage – temperature – low battery
Noise (at 1 m)<50 dBA at 1 m
Operating temperature0 ÷ 40 °C
Relative humidity5 – 95% no condensing
Output sockets4 IEC 10A
DATA
Weight15.6 kg
Dimensions (h w d)1Ux19″x460 mm

Series Table

MODELSVSR 800VSR 1100
POWER800 VA/640 W1100 VA/880 W
INPUT
Nominal voltage230 Vac (220, 240 V selectable)230 Vac (220, 240 V selectable)
Voltage tolerance162 V – 290 V162 V – 290 V
Frequency50/60 Hz with automatic selection50/60 Hz with automatic selection
Frequency tolerance±5% (3% to 10% configurable)±5% (3% to 10% configurable)
OUTPUT
Nominal voltage230 Vac (220, 240 V selectable)230 Vac (220, 240 V selectable)
Frequency50 or 60 Hz with automatic selection50 or 60 Hz with automatic selection
WaveformSinusoidalSinusoidal
BATTERIES
TypeVRLA AGM maintenance-free lead basedVRLA AGM maintenance-free lead based
Recharge time4-6 h4-6 h
OTHER FEATURES
Net weight (kg)1213
Gross weight (kg)14.515.5
Dimensions (WxDxH) (mm)19” x 420 x 1U19” x 420 x 1U
Packaged dimensions (WxDxH) (mm)595 x 540 x 140595 x 540 x 140
ProtectionsOverload – short-circuit – overvoltage – undervoltage – temperature – excessive low batteryOverload – short-circuit – overvoltage – undervoltage – temperature – excessive low battery
CommunicationsUSB / RS232 / slot for communications interfaceUSB / RS232 / slot for communications interface
Input plugs1 IEC 320 C141 IEC 320 C14
Output sockets4 IEC 320 C134 IEC 320 C13
StandardsEN 62040-1-1 and Directive 2014/35/EU; EN 62040-2 and Directive 2014/30/EUEN 62040-1-1 and Directive 2014/35/EU; EN 62040-2 and Directive 2014/30/EU
Operating temperature0 °C / +40 °C0 °C / +40 °C
Storage temperature -15 °C / 45 °C -15 °C / 45 °C
ColourBlackBlack
Relative humidity<95% non-condensing<95% non-condensing
Noise< 50 dBA< 50 dBA